Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole

Dyuthi/Manakin Repository

Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole

Show simple item record

dc.contributor.author Girish Kumar,K
dc.contributor.author Augustine, Pearl
dc.contributor.author John, Sareena
dc.contributor.author Radecki, Jerzi
dc.contributor.author Radecka, Hanna
dc.date.accessioned 2010-12-03T08:25:45Z
dc.date.available 2010-12-03T08:25:45Z
dc.date.issued 2008
dc.identifier.issn 0003-2719
dc.identifier.other Analytical Letters, 41: 1144–1157, 2008
dc.identifier.uri http://dyuthi.cusat.ac.in/xmlui/purl/1989
dc.description.abstract The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8mV=decade and 55.2mV=decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1×10-2-5×10-5 and 1×10-2-1×10-6). The sensors showed a fast response time of <30 sec and <45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 10 5M was obtained for PVC membrane sensor and 6.91 10 6M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method. en_US
dc.description.sponsorship Polish Academy of Sciences & Cochin University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Taylor & Francis en_US
dc.subject Carbon paste sensor en_US
dc.subject Ketoconazole en_US
dc.subject Molybdophosphoric acid en_US
dc.subject Pharmaceutical formulations en_US
dc.subject Polymeric membrane sensor en_US
dc.subject Potentiometry en_US
dc.title Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole en_US
dc.type Working Paper en_US
dc.contributor.faculty Science en_US
dc.identifier.url DOI: 10.1080/00032710802051983 en_US


Files in this item

Files Size Format View
Fabrication of potentiometric....pdf 205.3Kb PDF View/Open