DSpace About DSpace Software
 

Dyuthi @ CUSAT >
e-SCHOLARSHIP >
Instrumentation >
Faculty >
Dr. Jacob Philip >

Please use this identifier to cite or link to this item: http://purl.org/purl/2023

Title: An Inter-digital Capacitive Electrode Modified as a Pressure Sensor
Authors: Jacob, Philip
Ginson, T J
Technology
Keywords: Inter-digital capacitive electrode
E-field sensors
Touch/proximity sensors
Distributed pressure sensors
Issue Date: Dec-2008
Publisher: International Frequency Sensor Association
Abstract: Inter-digital capacitive electrodes working as electric field sensors have been developed for touch panel applications. Evaluation circuits to convert variations in electric fields in such sensors into computer compatible data are commercially available. We report development of an Interdigital capacitive electrode working as a sensitive pressure sensor in the range 0-120 kPa. Essentially it is a touch/proximity sensor converted into a pressure sensor with a suitable elastomer buffer medium acting as the pressure transmitter. The performance of the sensor has been evaluated and reported. Such sensors can be made very economical in comparison to existing pressure sensors. Moreover, they are very convenient to be fabricated into sensor arrays involving a number of sensors for distributed pressure sensing applications such as in biomedical systems.
URI: http://dyuthi.cusat.ac.in/xmlui/purl/2023
ISSN: 1726-5479
Appears in Collections:Dr. Jacob Philip

Files in This Item:

File Description SizeFormat
An inter-digital capacitive...pdf169.57 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback