Now showing items 1-13 of 13
Abstract: | This paper presents the design of a new type of corner reflector (CR) antenna and the experimental investigation of its radiation characteristics. The design involves the addition of planar parallel periodic strips to the two sides of a CR antenna. The position, angular orientation, and number of strips have a notable effect on the H-plane radiation characteristics of the antenna. Certain configurations of the new antenna are capable of producing very sharp axial beams with gain on the order of 5 dB over the square corner reflector antenna. A configuration that can provide symmetric twin beams with enhanced gain and reduced half-power beam width (HPBW) is also presented. |
URI: | http://dyuthi.cusat.ac.in/purl/2980 |
Files | Size |
---|---|
Dyuthi-P00415.pdf | (146.7Kb) |
Abstract: | The performance of circular, rectangular and cross irises for the coupling of microwave power to rectangular waveguide cavity resonators is discussed. For the measurement of complex permittivity of materials using cavity perturbation techniques, rectangular cavities with high Q-factors are required. Compared to the conventional rectangular and circular irises, the cross Iris coupling structure provides very high loaded quality factor for all the resonant frequencies. The proposes cross iris coupling structure enhances the accuracy of complex permittivity measurements. |
URI: | http://dyuthi.cusat.ac.in/purl/2976 |
Files | Size |
---|---|
Dyuthi-P00411.pdf | (510.6Kb) |
Abstract: | A novel cavity perturbation technique using coaxial cavity resonators for the measurement of complex permittivity of liquids is presented. The method employs two types of resonators (Resonator I and Resonator II). Resonator I operates in the frequency range 600 MHz-7 GHz and resonator II operates in the frequency range 4 GHz-14 GHz. The introduction of the capillary tube filled with the sample liquid into the coaxial resonator causes shifts in the resonance frequency and loaded Q-factor of the resonator. The shifts in the resonance frequency and loaded Q-factor are used to determine the real and imaginary parts of the complex permittivity of the sample liquid, respectively. Using this technique, the dielectric parameters of water and nitrobenzene are measured. The results are compared with those obtained using other standard methods. The sources of errors are analyzed. |
URI: | http://dyuthi.cusat.ac.in/purl/2981 |
Files | Size |
---|---|
Dyuthi-P00416.pdf | (750.3Kb) |
Abstract: | In the medical field, microwaves play a larger role for treatment than diagnosis. For the detection of diseases by microwave methods, it is essential to know the dielectric properties of biological materials. For the present study, a cavity perturbation technique was employed to determine the dielectric properties of these materials. Rectangular cavity resonators were used to measure the complex permittivity of human bile, bile stones, gastric juice and saliva. The measurements were carried out in the S and J bands. It is observed that normal and infected bile have different dielectric constant and loss tangent. Dielectric constant of infected bile and gastric juice varies from patient to patient. Detection and extraction of bile stone with possible method of treatment is also discussed. |
URI: | http://dyuthi.cusat.ac.in/purl/2982 |
Files | Size |
---|---|
Dyuthi-P00417.pdf | (759.2Kb) |
Abstract: | Dielectric properties of polyaniline at different frequencies were studied. Cavity perturbation technique was employed for the study. Poly aniline in the powder and pelletised forms were prepared under different environmental conditions. Different samples of poly aniline exhibit high conductivity. However. the conductivity of samples prepared under different environmental conditions is found to vary. All the samples in the powder form have high conductivity irrespective of the method of preparation. The high conductivity at microwave frequency makes it possible to be used for developing microwave components like filters. |
URI: | http://dyuthi.cusat.ac.in/purl/2978 |
Files | Size |
---|---|
Dyuthi-P00413.pdf | (620.0Kb) |
Abstract: | The radiation characteristics of a new type of hollow dielectric H-plane sectoral horn antenna are presented. Metallic strips of optimum length are loaded on the H-walls of the sectoral horns. The effects of strip loading for producing square patterns in the H plane are discussed. |
URI: | http://dyuthi.cusat.ac.in/purl/2977 |
Files | Size |
---|---|
Dyuthi-P00412.pdf | (115.5Kb) |
Abstract: | The detection of buried objects using time-domain freespace measurements was carried out in the near field. The location of a hidden object was determined from an analysis of the reflected signal. This method can be extended to detect any number of objects. Measurements were carried out in the X- and Ku-bands using ordinary rectangular pyramidal horn antennas of gain 15 dB. The same antenna was used as the transmitter and recei er. The experimental results were compared with simulated results by applying the two-dimensional finite-difference time-domain(FDTD)method, and agree well with each other. The dispersi e nature of the dielectric medium was considered for the simulation. |
URI: | http://dyuthi.cusat.ac.in/purl/2983 |
Files | Size |
---|---|
Dyuthi-P00419.pdf | (131.7Kb) |
Abstract: | Ionic polymers (ionomers) with interesting characteristics are emerging as important commercial polymers. Ionomers have the unique ability to behave as cross-linked materials at ambient temperatures and to melt and flow at elevated temperatures like thermoplastics. The complex permittivity and conductivity of a class of ionomers at microwave frequencies are determined using the cavity perturbation technique and the results are presented. |
URI: | http://dyuthi.cusat.ac.in/purl/2984 |
Files | Size |
---|---|
Dyuthi-P00421.pdf | (128.1Kb) |
Abstract: | Conducting polymers are excellent microwave absorbers and they show technological advantage when compared with inorganic electromagnetic absorbing materials, being light weight , easily processable, and the ability of changing the electromagnetic properties with nature and amount of dopants, synthesis conditions, etc. In this paper we report the synthesis, dielectric properties, and expected application of conducting composites based on polyaniline (PAN). Cyclohexanone soluble conducting PAN composites of microwave conductivity 12.5 S/m was synthesized by the in situ polymerization of aniline in the presence of emulsion grade polyvinyl chloride. The dielectric properties of the composites, especially the dielectric loss, conductivity, dielectric heating coefficient , absorption coefficient, and penetration depth, were studied using a HP8510 vector network analyzer. The microwave absorption of the composites were studied at different frequency bands i.e, S, C, and X bands (2-12 GHz). The absorption coefficient was found to be higher than 200 m -' and it can be used for making microwave absorbers in space applications |
URI: | http://dyuthi.cusat.ac.in/purl/875 |
Files | Size |
---|---|
Honey John and ... lyaniline composites...PDF | (3.966Mb) |
Abstract: | HIV/AIDS is one of the most destructive epidemics in ever recorded history claims an estimated 2.4 –3.3 million lives every year. Even though there is no treatment for this pandemic Elisa and Western Blot tests are the only tests currently available for detecting HIV/AIDS. This article proposes a new method of detecting HIV/AIDS based on the measurement of the dielectric properties of blood at the microwave frequencies. The measurements were made at the S-band of microwave frequency using rectangular cavity perturbation technique with the samples of blood from healthy donors as well as from HIV/AIDS patients. An appreciable change is observed in the dielectric properties of patient samples than with the normal healthy samples and these measurements were in good agreement with clinical results. This measurement is an alternative in vitro method of diagnosing HIV/AIDS using microwaves. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/2052 |
Files | Size |
---|---|
A novel method of detecting...pdf | (156.8Kb) |
Abstract: | Hydroxyapatite (HAp, Ca10(PO4)6(OH)2) bioceramic and chitosan (poly [( -1-4) D-glucosamine]) biopolymer show good biocompatibility in vivo. They have biological origin and show excellent interactions with microwave. Microwave study of HAp made using different drying techniques and their composites with chitosan in the ISM band is presented. Pastes are made using HAp and chitosan with different ratios of mixing. The dielectric properties of this composites match with that of human fat, collagen tissues. Some of the compositions exhibit dielectric property close to that of natural bone. This makes them more biocompatible and better substitutes for natural bone. Thus composite bioceramics can be considered as phantom model constituents for imaging purposes. Their dielectric properties prove that they are biocompatible. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/2050 |
Files | Size |
---|---|
Biocompatibilit ... oxyapatite-chitosan....pdf | (306.1Kb) |
Abstract: | This article reports a new method of analyzing pericardial fluid based on the measurement of the dielectric properties at microwave frequencies. The microwave measurements were performed by rectangular cavity perturbation method in the S-band of microwave frequency with the pericardial fluid from healthy persons as well as from patients suffering from pericardial effusion. It is observed that a remarkable change in the dielectric properties of patient samples with the normal healthy samples and these measurements were in good agreement with clinical analysis. This measurement technique and the method of extraction of pericardial fluid are simple. These results give light to an alternative in-vitro method of diagnosing onset pericardial effusion abnormalities using microwaves without surgical procedure. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/2051 |
Files | Size |
---|---|
Human pericardial fluid at...pdf | (81.27Kb) |
Abstract: | This article reports a new in vitro bile analysis based on the measurement of the dielectric properties at microwave frequencies. The measurements were made using rectangular cavity perturbation technique at the S-band of microwave frequency with the different samples of bile obtained from healthy persons as well as from patients. It is observed that an appreciable change in the dielectric properties of patient’s samples with the normal healthy samples and these measurements were in good agreement with clinical analysis. These results prove an alternative in-vitro method of detecting bile abnormalities based on the measurement of the dielectric properties of bile samples using microwaves without surgical procedure. |
URI: | http://dyuthi.cusat.ac.in/xmlui/purl/2049 |
Files | Size |
---|---|
Detection of biliary functional...pdf | (162.2Kb) |
Now showing items 1-13 of 13
Dyuthi Digital Repository Copyright © 2007-2011 Cochin University of Science and Technology. Items in Dyuthi are protected by copyright, with all rights reserved, unless otherwise indicated.