dc.contributor.author |
Girish Kumar,K |
|
dc.contributor.author |
Joseph, Renjini |
|
dc.date.accessioned |
2010-12-03T09:07:50Z |
|
dc.date.available |
2010-12-03T09:07:50Z |
|
dc.date.issued |
2009-06-01 |
|
dc.identifier.issn |
0003-2719 |
|
dc.identifier.other |
Analytical Letters, 42: 2309–2321, 2009 |
|
dc.identifier.uri |
http://dyuthi.cusat.ac.in/xmlui/purl/1991 |
|
dc.description.abstract |
A metalloporphyrin incorporated carbon paste sensor has been developed
for the determination of metronidazole benzoate (MTZB). Zn(II) complex
of 5,10,15,20-tetrakis (3-methoxy-4-hydroxy phenyl) porphyrin (TMHPP) was
used as the active material. The MTZB gave a well-defined reduction peak at
- 0.713V in 0.1 mol l -1 phosphate buffer solution of pH around 7. Compared
with bare carbon paste electrode (CPE), the TMHPP Zn(II) modified electrode
significantly enhanced the reduction peak current of MTZB as well as lowered
its reduction potential. Under optimum conditions the reduction peak current
was proportional to MTZB concentration over the range 1×10-3 mol1-1 to 1×10-5mol1-1. The detection limit was found to be 4.36×10-6mol1-1
. This
sensor has been successfully applied for the determination of MTZB in pharmaceutical
formulations and urine samples. |
en_US |
dc.description.sponsorship |
Cochin University of Science
and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Taylor & Francis |
en_US |
dc.subject |
Carbon paste electrode |
en_US |
dc.subject |
cyclic voltammetry |
en_US |
dc.subject |
electrochemical reduction |
en_US |
dc.subject |
metalloporphyrin |
en_US |
dc.subject |
metronidazole benzoate |
en_US |
dc.title |
Electrochemical Reduction and Voltammetric Determination of Metronidazole Benzoate at Modified Carbon Paste Electrode |
en_US |
dc.type |
Working Paper |
en_US |
dc.contributor.faculty |
Science |
en_US |
dc.identifier.url |
DOI: 10.1080/00032710903137426 |
en_US |