Behaviour of laterised normal and self compacting concrete subjected to elevated temperatures

Dyuthi/Manakin Repository

Behaviour of laterised normal and self compacting concrete subjected to elevated temperatures

Show simple item record

dc.contributor.author Mathews, M Paul
dc.contributor.author Dr. George, Mathew
dc.date.accessioned 2014-02-25T04:15:18Z
dc.date.available 2014-02-25T04:15:18Z
dc.date.issued 2012-03
dc.identifier.uri http://dyuthi.cusat.ac.in/purl/3262
dc.description Division of Safety and Fire Engineering School of Engineering,Cochin University of Science and Technology. en_US
dc.description.abstract Concrete is a universal material in the construction industry. With natural resources like sand and aggregate, fast depleting, it is time to look for alternate materials to substitute these in the process of making concrete. There are instances like exposure to solar radiation, fire, furnaces, and nuclear reactor vessels, special applications like missile launching pads etc., where concrete is exposed to temperature variations In this research work, an attempt has been made to understand the behaviour of concrete when weathered laterite aggregate is used in both conventional and self compacting normal strength concrete. The study has been extended to understand the thermal behaviour of both types of laterised concretes and to check suitability as a fire protection material. A systematic study of laterised concrete considering parameters like source of laterite aggregate, grades of Ordinary Portland Cement (OPC) and types of supplementary cementitious materials (fly ash and GGBFS) has been carried out to arrive at a feasible combination of various ingredients in laterised concrete. A mix design methodology has been proposed for making normal strength laterised self compacting concrete based on trial mixes and the same has also been validated. The physical and mechanical properties of laterised concretes have been studied with respect to different variables like exposure temperature (200°C, 400°C and 600°C) and cooling environment (air cooled and water cooled). The behaviour of ferrocement elements with laterised self compacting concrete has also been studied by varying the cover to mesh reinforcement (10mm to 50mm at an interval of 10mm), exposure temperature and cooling environment. en_US
dc.description.sponsorship Cochin University of Science and Technology. en_US
dc.language.iso en en_US
dc.publisher Cochin University of Science and Technology en_US
dc.subject Concrete en_US
dc.subject Ground Granulated Blast Furnace Slag, Self Compacting Concrete en_US
dc.subject Laterised concrete en_US
dc.title Behaviour of laterised normal and self compacting concrete subjected to elevated temperatures en_US
dc.type Thesis en_US